Fast answer

If the sequencer echoes the Prophecy's MIDI OUT back to its MIDI IN, set GLB-8 [MIDI] → Local to OFF. This removes the direct keyboard path while the returned MIDI notes still play the sound engine.

Try these checks

  1. Confirm your sequencer is echoing incoming notes back to the Prophecy.
  2. Open GLB-8 [MIDI] and set Local to OFF for this routed setup.
  3. Play a key and confirm one note sounds through the sequencer path. Restore Local to ON when using the keyboard without an echo path.

Diagnose it

Is MIDI echo or monitoring sending the keyboard notes back to the Prophecy?

Yes: Set Local to OFF in GLB-8 [MIDI].

No: Leave Local ON and inspect the sequencer's duplicate tracks or monitoring settings.

What should happen

One note sounds for each key press through the sequencer route.

Why this happens

Korg specifically describes Local OFF as the way to avoid dual triggering when a sequencer echoes transmitted notes back.

If it still doesn’t work

Check the connections and settings described above. If your device behaves differently, email us with its model, firmware version and the steps you tried.

All Prophecy fixes

More about Prophecy

Korg Prophecy guide · MIDI reference

Similar symptoms on other gear

These guides cover other models. Use the instructions for the device you are setting up.

References

Sources & review

Sources reviewed: . Documentation does not replace a physical hardware test.

Sections reviewed: GLB-8, p. 139.