Set Clock Source to Auto (MIDI), connect the master’s MIDI OUT to the minilogue xd MIDI IN, and make sure the master sends timing clock.
Try these checks
- Connect the master MIDI OUT to minilogue xd MIDI IN.
- Open Global Edit clock settings.
- Set Clock Source to Auto (MIDI).
- Start the master and test tempo changes.
Diagnose it
Is Clock Source Auto (MIDI)?
Yes: Check the master clock-transmit setting and cable direction.
No: Set Auto (MIDI) and retest.
What should happen
The minilogue xd follows received timing clock when it is available.
Why this happens
Korg documents Auto (MIDI) as following received timing clock and using its internal clock otherwise.
If it still doesn’t work
Check the connections and settings described above. If your device behaves differently, email us with its model, firmware version and the steps you tried.
All minilogue xd fixesMore about minilogue xd
Similar symptoms on other gear
These guides cover other models. Use the instructions for the device you are setting up.
Sources & review
Sources reviewed: . Documentation does not replace a physical hardware test.
- minilogue xd Owner’s Manual · Korg · last checked 2026-09-26 · Open PDF
Sections reviewed: Owner’s Manual, Global Edit clock settings.