In UTILITY:SYNC/TEMPO, set TempoSync to MIDI for the DIN MIDI IN, or AUTO if you deliberately want automatic source selection. Then confirm the other device is transmitting MIDI clock.

Try these checks

  1. Press UTILITY and open SYNC/TEMPO.
  2. Set TempoSync to MIDI for a MIDI IN source; use AUTO only when automatic selection is intended.
  3. Connect the master’s MIDI OUT to TR-8S MIDI IN.
  4. Start the master and verify it transmits MIDI clock.

Diagnose it

Is TempoSync set to MIDI or AUTO?

Yes: Confirm the source’s clock output and the DIN cable direction.

No: Choose MIDI for DIN clock input, then retest.

Are both USB and MIDI clock connected while using AUTO?

Yes: USB takes priority in AUTO; remove or account for the competing USB clock.

No: Check the master’s clock-transmit setting.

What should happen

The TR-8S tempo synchronizes to MIDI clock received at MIDI IN.

Why this happens

Roland documents MIDI as the MIDI-IN tempo source and notes that USB has priority when both inputs supply clock in AUTO.

If it still doesn’t work

Check the connections and settings described above. If your device behaves differently, email us with its model, firmware version and the steps you tried.