Choose Ext in MIDI FILTER for external clock, then press WRITE. If USB and DIN both supply clock, KP3+ uses USB.
Try these checks
- Press SHIFT + PROGRAM MEMORY 4 to open MIDI FILTER.
- Select the clock entry with PROGRAM/BPM, press the knob to enter it, then choose Ext and press WRITE to save.
- Send clock through the intended input. Stop an unwanted USB clock if you are trying to follow DIN.
Diagnose it
Are both USB and DIN supplying clock?
Yes: USB takes priority; stop the unwanted source.
No: Check Ext selection and the sender's clock output.
What should happen
KP3+ follows the available external clock, with documented USB priority.
Why this happens
The clock filter chooses internal, external or automatic timing independently of the connection.
If it still doesn’t work
Check the connections and settings described above. If your device behaves differently, email us with its model, firmware version and the steps you tried.
All KAOSS PAD KP3+ fixesMore about KAOSS PAD KP3+
Similar symptoms on other gear
These guides cover other models. Use the instructions for the device you are setting up.
Sources & review
Sources reviewed: . Documentation does not replace a physical hardware test.
- KAOSS PAD KP3+ Owner's Manual · Korg · KP3+ multilingual Owner's Manual · English MIDI section · last checked 2026-10-07
Sections reviewed: MIDI FILTER and MIDI clock, p. 21.