Model scopeSH-4d Version 2.00 Owner's Manual scope. Physical device combinations and behavior outside this edition are not verified. Only sourced values are shown. Check each claim’s verification state before relying on it.

Quick reference

Sync Mode
AUTO, INT, MIDI or USB; EXT CLK IN overrides the selection.
Manufacturer documented
TEMPO/SYNC, p. 77
Sync Out
Outgoing clock routing is separate from Sync Mode.
Manufacturer documented
TEMPO/SYNC, p. 77
Direct USB keyboard
USB HOST for a direct USB MIDI keyboard is not supported.
Manufacturer documented
Remote Kbd, p. 78
Part reception
Parts 1–4 and R have separate receive-channel settings.
Manufacturer documented
MIDI, p. 77

Clock source and analog priority

Manufacturer documented

SYSTEM SETTINGS → TEMPO/SYNC separates Sync Mode from Sync Out. The first selects incoming timing; the second selects outgoing MIDI clock ports.

A cable in EXT CLK IN makes that input take priority regardless of Sync Mode. Check it when MIDI or USB sync appears to be ignored.

External keyboard and USB

Manufacturer documented

Remote Kbd selects MIDI IN or USB for an external keyboard acting in place of the built-in keys. Follow Roland's instruction to match the keyboard's transmit channel to Ctrl Ch for that mode.

SH-4d does not provide USB HOST for a directly connected USB MIDI keyboard. Its USB input can receive from a computer instead. The USB Driver setting requires a restart when changed.

Browse SH-4d fixes

References

Sources & review

Sources reviewed: . Documentation does not replace a physical hardware test.

Sections reviewed: TEMPO/SYNC, p. 77; Remote Kbd, p. 78; MIDI, p. 77; SYSTEM SETTINGS → TEMPO/SYNC, p. 77; SYSTEM SETTINGS, pp. 77–78.