Elektron Syntakt MIDI
Find Elektron Syntakt clock, transport, port and channel settings, with manufacturer documentation for each part of the route.
Published by MIDIrock.xyz · About Pete and the site · Page updated
Quick reference
- Incoming clock
- CLOCK RECEIVE and TRANSPORT RECEIVE are independent.
- Manufacturer documented
- §14.4.1, pp. 75–76
- DIN output mode
- MIDI, DIN24 and DIN48 serve different purposes.
- Manufacturer documented
- §14.4.2, p. 76
- Incoming MIDI route
- INPUT FROM can include MIDI, USB, both, or neither.
- Manufacturer documented
- §14.4.2, p. 76
- Active-track playing
- AUTO CHANNEL addresses the currently selected track.
- Manufacturer documented
- §14.4.3, p. 77
Clock and transport
Manufacturer documentedIn SETTINGS → MIDI CONFIG → SYNC, CLOCK RECEIVE follows incoming tempo and TRANSPORT RECEIVE follows incoming start/stop. These are separate switches. CLOCK SEND and TRANSPORT SEND control the outgoing side.
PORT CONFIG → INPUT FROM selects where incoming MIDI is accepted. Receiving over USB requires a USB MIDI-capable mode in USB CONFIG.
Ports and channels
Manufacturer documentedOUT PORT FUNCTIONALITY must be MIDI for ordinary MIDI output. DIN24 and DIN48 are synchronization formats, not MIDI-message outputs. OUTPUT TO also needs to include the intended destination.
AUTO CHANNEL lets an external controller play the currently selected track. Match the controller's channel to that setting and enable RECEIVE NOTES. Dedicated track channels are separate from the MIDI machine's sequencer channel.
Sources & review
Sources reviewed: . Documentation does not replace a physical hardware test.
- Syntakt User Manual · Elektron · OS 1.40 · 4 March 2026 · last checked 2026-10-07
Sections reviewed: §14.4.1, pp. 75–76; §14.4.2, p. 76; §14.4.3, p. 77; §14.4.1–14.4.2, pp. 75–76; §14.9.1, p. 82; §14.4.2–14.4.3, pp. 76–77.