Arturia MicroFreak MIDI
Find Arturia MicroFreak MIDI input and output channels, Local Control, USB MIDI and parameter-message guidance from User Manual 5.0.1.
Published by MIDIrock.xyz · About Pete and the site · Page updated
Quick reference
- MIDI input channel
- All, 1–16 or none, set in Utility → MIDI → Input Chan
- Manufacturer documented
- User Manual 5.0.1, §17.5
- MIDI output channel
- 1–16, set in Utility → MIDI → Output Chan
- Manufacturer documented
- User Manual 5.0.1, §17.5
- Local Control
- OFF sends keyboard/control MIDI but disconnects the internal sound engine
- Manufacturer documented
- User Manual 5.0.1, §17.4
- USB MIDI
- USB MIDI class-compliant; iPad use requires an appropriate camera/USB adapter cable
- Manufacturer documented
- User Manual 5.0.1, Welcome and introduction
- Selected parameter messages
- Cutoff CC23, Resonance CC83, Hold CC64 and keyboard pressure via aftertouch
- Manufacturer documented
- Arturia support: Functions and MIDI parameters
Channels and Local Control
Manufacturer documentedUtility → MIDI provides separate Input Chan and Output Chan settings. Arturia’s manual gives Utility → MIDI → Input Chan and Utility → MIDI → Output Chan as the places to match a DAW, controller or destination channel.
Local Control OFF disconnects the keyboard and controls from the MicroFreak sound engine while they continue to transmit MIDI. Arturia documents this as a way to avoid double triggering when a sequencer echoes the keyboard’s notes back to the synth.
USB MIDI and documented parameter messages
Manufacturer documentedThe MicroFreak is documented as USB MIDI class-compliant. For an iPad, Arturia specifies an appropriate camera/USB adapter cable; confirm the host device’s requirements before choosing an adapter.
Arturia’s MIDI FAQ lists individual parameter messages. For example, Cutoff is CC23, Resonance is CC83, Hold is CC64 and keyboard pressure uses aftertouch. Use the official list for any parameter not named here rather than guessing from the front panel.
Sources & review
Sources reviewed: . Documentation does not replace a physical hardware test.
- MicroFreak User Manual, version 5.0.1 · Arturia · Version 5.0.1 · last checked 2026-09-26 · Open PDF
- MicroFreak General Questions — MIDI parameters · Arturia · last checked 2026-09-26
Sections reviewed: User Manual 5.0.1, §17.5; User Manual 5.0.1, §17.4; User Manual 5.0.1, Welcome and introduction; Arturia support: Functions and MIDI parameters; User Manual 5.0.1, §§17.4–17.5; Arturia support: MicroFreak General Questions — Functions and MIDI parameters.